====== Using APC UPS on Debian GNU/Linux ====== | ====== Using APC UPS on Debian GNU/Linux ====== | ||
+ | |||
+ | My home server system is powered through an UPS unit, the system is composed of the following: | ||
+ | |||
+ | * A **Dell PowerEdge T110** with two 4 Tb hard disks, running Debian GNU/Linux. | ||
+ | * A **DSL router**. | ||
+ | * An **8 ports switch**. | ||
+ | |||
+ | All the equipments drawn about **62 W** during daily operation. In several years I tested the following two APC UPSs: | ||
+ | |||
+ | * In 2006 I purchased an **APC Smart-UPS 750 USB**. | ||
+ | * In 2022 I purchased an **APC Back-UPS CS 500**. | ||
+ | |||
+ | Both units support monitoring through an **USB cable** and the **apcupsd** program, it seems that the Back-UPS CS 500 does not support the periodic self-test. | ||
+ | |||
+ | The **APC Back-UPS CS 500** should be able to supply power for about 30 minutes; doing battery calibration with the **apctest** tool, it took about 10 minutes to drop from 100% battery charge to 70%. | ||
====== APC Smart-UPS 750 USB ====== | ====== APC Smart-UPS 750 USB ====== | ||
- | L' | + | L' |
Installare il pacchetto **apcupsd**. Per visualizzare convenientemente lo stato dell' | Installare il pacchetto **apcupsd**. Per visualizzare convenientemente lo stato dell' | ||
Line 50: | Line 65: | ||
< | < | ||
- | BATTERYLEVEL | + | BATTERYLEVEL |
MINUTES 8 | MINUTES 8 | ||
</ | </ | ||
Line 86: | Line 101: | ||
^ New battery date MM/ | ^ New battery date MM/ | ||
- | |||
| 08/ | | 08/ | ||
| 11/ | | 11/ | ||
Line 210: | Line 224: | ||
Select function number: | Select function number: | ||
</ | </ | ||
+ | |||
+ | The two most important functions are the **#10 battery calibration** and the **#12 self-test interval**. Battery calibration must be initiated with a fully charged battery and the normal load (it should be above 10%); it will end when battery drops below about 25%. Unfortunately it seems that the **Back-UPS CS 500** model does not support the **periodic self-test**, | ||
+ | |||
+ | ^ New battery date (MM/ | ||
+ | | 04/ | ||
+ | |||
====== Voltaggio batterie ======= | ====== Voltaggio batterie ======= | ||