The outer diameter refers to the overall cable, including the insulator. The AWG gauge is calculated measuring the diameter of the single strand and calculating the overall cross-sectional area; then the nearest value is looked into the [[wp> | The outer diameter refers to the overall cable, including the insulator. The AWG gauge is calculated measuring the diameter of the single strand and calculating the overall cross-sectional area; then the nearest value is looked into the [[wp> | ||
- | **NOTICE**: The **19 AWG 30/34** notation means that there are 30 strands, each strand is an AWG #34 wire (0.160 mm diameter), the overall cross-section | + | **NOTICE**: The **19 AWG 30/34** notation means that there are 30 strands, each strand is an AWG #34 wire (0.160 mm diameter), the overall cross-sectional |
**NOTICE**: The **ampacity** reported in the table is the maximum electrical current in amperes that the conductor can carry for **2 meters**, mantaining the **voltage drop below 2%**. The formulas for calculating the voltage drop for a copper conductor (coefficient ρ = 1.68*10^-8 Ωm) are: | **NOTICE**: The **ampacity** reported in the table is the maximum electrical current in amperes that the conductor can carry for **2 meters**, mantaining the **voltage drop below 2%**. The formulas for calculating the voltage drop for a copper conductor (coefficient ρ = 1.68*10^-8 Ωm) are: | ||
- | * cable resistance **Ω** = (1,68 * 10^-8 **Ωm**) * (lenght **m**) / (cross sectional **m²**) | + | * cable resistance **Ω** = (1,68 * 10^-8 **Ωm**) * (cable lenght **m**) / (cross sectional **m²**) |
* voltage drop **v** = (current **A**) * (cable resistance **Ω**) | * voltage drop **v** = (current **A**) * (cable resistance **Ω**) | ||